Hytec Electronics Ltd. |
|
CAMAC 80 and 81 Quad Word Generator Product Description This single width CAMAC module contains upto 4 24–bit switch registers, 3 of which maybe located internally on the module PCB and the 4th on the front panel. The 3 internal sets may be preset through module side cover cutouts and are intended for multi–user code settings, the front panel register is intended for random entry of data. A 25th switch allow users to enable and set LAM, an internal switch enables users to preset the sub–address order for reading the registers. Type 81 also contains a 24 bit read/write register and front panel LED display. Features
Function and Sub-address Command Set
(All Function Codes and Sub–addresses are fully decoded, however, on reduced versions of the Generator, the X and Q response will appear on registers that are not present). Operating Environment The module should normally be operated in the standard CAMAC temperature environment (+10 C to + 45 C), forced air cooling is not required. The module requires +6 volts at approximately 700mA worst case. Order Information Type 80 full specification but without LED displayed R/W register. Type 81 full specification. Special versions of type 80 and 81 can be supplied with 1 or more of the internal registers omitted, thus reducing cost and complexity. For full details of prices and deliveries please contact our sales offices. |
| Hytec Electronics Ltd Post : 5 Cradock Road, Reading, Berkshire, RG2 0JT, England. Phone : +44 (0)118 9757770 Fax : +44 (0)118 9757566 |