Product -- VME64x / Transition Board Digital

VME64x resulted in significant enhancements to existing specifications, satisfying the demand for more flexible I/O capability, rugged mechanics with EMC/ESD protection and larger address capability, while at the same time making it easier to use with geographical addressing and Hot-Swap.

The Carrier Board plugs in from the front of the crate in the normal way. As it is inserted, ESD protection contacts discharge any dangerous voltage safely to earth. The card begins to contact the P1 and P2 connectors and long pre-charge pins provide power to the back-end circuitry to prepare the Hot-Swap logic. While the card is levered into position by the inject/eject handles, the Hot-Swap controller is powering on the card logic and checking the supply rails allowing carrier card replacement without the need to power down. In VxWorks and EPICS systems, our software drivers will automatically re-instate the new hardware.

Transition Boards boards provide the connection required for rear I/O functions and allow signal conditioning and plant isolation to be added. All Hytec transition cards use the same inexpensive 50-way SCSI II  connector for I/O connection on the rear panel, so that inexpensive, commercially available cables can be used to connect to terminal blocks, such as our 8901 DIN-rail mounted Terminal Board.

To add to the flexibility of VME64x, we have introduced a number of plug-in cards based on the Industry Pack format. Industry Packs (IP) are about the size of a credit card and provide a range of I/O functions. The IP cards are accommodated on carrier boards such as the 8001/8002/8003 which provide sites for two or four packs. An open specification defines the key characteristics ensuring compatibility between suppliers. An ID PROM includes identification and in some cases calibration data, which makes auto-configuration with application software a possibility. They have connectors that are keyed for ease of installation. Software support is available from Hytec.

8301.jpg

VTB8301

Description: Isolated Digital Input Transition Board

8302.jpg

VTB8302

Description: Digital Input/Output Transition Board

8303.jpg

VTB8303

Description: Isolated Digital Output Transition Board

8304.jpg

VTB8304

Description: Straight-Through Transition Board

8305.jpg

VTB8305

Description: Isolated Digital Input/Output Transition Board

8353.jpg

VTB8353

Description: Isolated Digital Output Transition Board (160mm Depth)

8354.jpg

VTB8354

Description: Straight-Through Transition Board (160mm Depth)